WearCheck earns DGA (Dissolved Gas Analysis) accreditation

10th June 2025

     

Font size: - +

This article has been supplied.

(Virtual Showroom) WearCheck, the specialist condition monitoring company, is now accredited to perform DGA, or Dissolved Gas Analysis, for transformers, following a recent assessment by SANAS (South African National Accreditation System).

The company’s Johannesburg transformer oil testing laboratory now has ISO/IEC 17025 accreditation for testing DGA, moisture, acidity, dielectric strength, and PCBs (polychlorinated biphenyls).

Gert Nel, WearCheck’s transformer division manager, outlines the importance of DGA in transformer maintenance: ‘Dissolved Gas Analysis is used mostly for fault detection in transformers, and it is critically important that the analysis is accurate. By analysing the gases dissolved in the transformer’s oil, we gain important clues about the health of the transformer.

‘WearCheck is pioneering the way in transformer maintenance in Southern Africa, and this SANAS accreditation is a powerful attribute for our laboratories.’

Transformers help to transfer electricity over long distances, often playing key roles in the infrastructure of a region and ensuring power supply to cities, industrial plants and other critical users. Therefore, early detection of faults and potential failures is very important.

DGA saves transformer operators money on avoidable repairs, time, and helps avoid greater problems such as interrupted power supply. It also helps prolong the life of the transformer.

Nel explains the process, ‘Small amounts of gases are formed in the oil when a transformer is in operation. Using DGA, hidden problems inside the transformer are revealed by detecting the gases in the oil.

‘Some of the common transformer problems and the associated gases include oil overheating (ethane and ethylene), insulation paper overheating (carbon monoxide, carbon dioxide, and acetic acid gases), air ingress (oxygen and nitrogen), and partial discharge (hydrogen gas and carbon monoxide gases), sparking and arcing type of faults (methane and acetylene).

‘The early detection of potential transformer faults enables remedial action to be implemented, and major failures averted.

Case study

Nel discusses a WearCheck client that only requested for M/A/D (moisture / dielectric / acidity) results over the years, and when the very first DGA was done, it showed a critical error.

‘The DGA indicated an actual internal electrical problem, however the client wasn’t convinced and even did two oil changes in 24 months, hoping this would solve the problem. Changing the oil did not fix the problem, however. All this did was to remove evidence of the problem. The actual electrical fault was still present in the transformer, and a and a new trend was then required after the oil was changed.

‘In this case, the DGA was indicative of an actual fault, and the oil changes did not fix the fault. This is very important, as a lot of clients only test for M/D (moisture / dielectric), and not the full DGA analysis. Eventually, the client made the decision to include all tests in their ongoing maintenance plan, and took the recommended remedial action to fix the electrical fault.

Edited by Creamer Media Reporter

Comments

Showroom

Weir
Weir

Weir is a global leader in mining technology. We recognise that our planet’s future depends on the transition to renewable energy, and that...

VISIT SHOWROOM 
SABAT
SABAT

From batteries for boats and jet skis, to batteries for cars and quad bikes, SABAT Batteries has positioned itself as the lifestyle battery of...

VISIT SHOWROOM 

Latest Multimedia

sponsored by

Magazine round up | 25 July 2025
Magazine round up | 25 July 2025
25th July 2025

Option 1 (equivalent of R125 a month):

Receive a weekly copy of Creamer Media's Engineering News & Mining Weekly magazine
(print copy for those in South Africa and e-magazine for those outside of South Africa)
Receive daily email newsletters
Access to full search results
Access archive of magazine back copies
Access to Projects in Progress
Access to ONE Research Report of your choice in PDF format

Option 2 (equivalent of R375 a month):

All benefits from Option 1
PLUS
Access to Creamer Media's Research Channel Africa for ALL Research Reports, in PDF format, on various industrial and mining sectors including Electricity; Water; Energy Transition; Hydrogen; Roads, Rail and Ports; Coal; Gold; Platinum; Battery Metals; etc.

Already a subscriber?

Forgotten your password?

MAGAZINE & ONLINE

SUBSCRIBE

RESEARCH CHANNEL AFRICA

SUBSCRIBE

CORPORATE PACKAGES

CLICK FOR A QUOTATION







sq:0.118 0.194s - 132pq - 2rq
Subscribe Now